Background

Every two years, SUM libraries conduct a comprehensive survey to receive feedback from the faculty, students and staff with regards to the libraries' services. With the data collected, SMU libraries hope to gain some insights so that they can enhance their existing services and meet the emerging needs of SMU faculty, students and staff.

However, the past reports were not able to give a comprehensive and condensed summary for the SMU libraries as they are mainly made-up of pages of tables. With the information overload, it becomes difficult for the SMU libraries to get the essential overview of which area they should focus on improving.

Objectives

With the massive amount of data being collected by the various sensors, there's definitely no way any GAStech employee can deal with the data to discover relationships or patterns without using any visualization tools. Hence, using all the visualization and analytical technique that I have learned in class, I aim to create an interactive data visualization to help GAStech management to be able to see patterns/identify anomalies/connections to better understand its operations in order to make better and informed decision.

With this interactive visualization, departments such as Security will be able to keep track of employee movements within the building to ensure that they are safe and also to prevent any unauthorized access to areas/zones that are prohibited. Furthermore, facility managers and executives could possibly identify areas that can improve the office environment such as to save costs and also to provide a conducive working environment for all GAStech employees.

Information Gathering

Looking at the given description of this challenge, there are some key information mentioned that are helpful and critical for my investigation.

  • Staff members are required to wear proximity (prox) cards while in the building.
  • The building is instrumented with passive prox card readers that cover individual building zones.
  • Rosie – a free robotic mail delivery system is equipped with a mobile prox sensor, which identifies the prox cards in the areas she travels through.

Based on the given data, like any visualization processes, it is imperative and critical to understand and look through the data before using any visualization software. I will be using Tableau as my visualization software and there are some work to be done on the given datasets before I plot my visualizations.

Data Preparation

Employee List & Fixed/Mobile Proximity Data

Data doesn’t always come ready for analysis. As many of you have experienced, some data needs a lot of work before it can be sensibly analyzed. To begin with, Employee List provided names in the format of Last Name and First Name. Therefore, the first thing I did to better identify these people, I used the Excel CONCATENATE () function to join all of them into a unique single column called Full Name (First Name – Last Name) format. This is because among the employees there are people with similar first or last names.

1 ky.png

Moving forward, I went on to find out how does a typical day look like for a GAStech employees. With the above information provided by the Employee list, it is only possible for me to make assumption that all employees are staying in their respective office throughout the whole day which is highly unlikely the case. As such, I went ahead to investigate further on other available datasets hoping to spot any patterns or relationships. Given the information from the case, we know that all employees are required to wear a proximity card while they are in the building, and proximity detectors have been installed throughout the building to enhance the safety and security of its employees. There are two types of proximity sensors, fixed sensors that register when a proxy card crosses a boundary and a mobile sensor reader that moves throughout the building to detect and record any available proxy cards within its vicinity. Both proxOut-MC2.csv and proxMobileOut.csv contains a field name: prox-id that could possibly help us to identify the whereabouts of an individual employee together with their given timestamp. Hence, I have created a new column name: prox-id in the Employee list using Excel formula as shown below:

2 ky.png

With that, we are able to map the prox-id in the Employee List with the proxOut and proxMobileOut lists. Although I have managed to create the prox-id column, I still need to manually locate and make changes to those inconsistent prox-ids that are either wrong in spelling or contains extra characters (e.g.”- “, or <space>,”.”). This is to avoid inaccuracy of information being retrieved when analysing data.

After the first batch of data cleaning, I move on to investigate what are the typical patterns that I could find based on the given proximity card data. The proximity card data comprises of two separate .csv files – proxOut-MC2.csv (contains the Fixed-prox data) and proxMobileOut.csv (contains the Mobile prox data). Given the x, y coordinates in the mobile prox dataset, we can easily plot it onto tableau and add the different background images on to it for better visualization and clarity. Additionally, we also find out that the mobile robot, Rosie operates in two different shifts, hence the data collected by Rosie is from Morning: 0900H – 1000H and Afternoon: 1400H – 1500H respectively.

After that, I move on to plot the visualizations for the fixed-proximity dataset. However, we are not given the x, y coordinates this time, so I spent quite a long time trying to figure out how to create those coordinates. Eventually, I would like to give credit to one of my fellow classmate, Gwendoline Tan, as I’ve gotten valuable insights on how to create them. Refer to the steps on her page.

Screenshot
Steps Taken
3 ky.png

First of all, the (x,y) coordinates are based per floor with the lower left of the provided map being (0,0) and the upper right being (189,111). Thus, I have cropped the pictures of ProxZones F1, F2, F3 and resized them into (189,111) use Paint Tool. I then proceed to use the tool provided from this Website:https://tableauandbehold.com/2015/04/13/creating-custom-polygons-on-a-background-image/ so as to create custom polygons based on the background image and retrieve the vertices of each polygon that I’ve drawn. The data is shown in figure 3 – with field names (Identifier, Path_ID, X, Y). In my case, I am drawing the outlines for the various zones of each floor.

4 ky.png

After which, I imported the data into tableau to retrieve the center point of the x, y coordinates by floors and zones respectively.However, there are some datapoints that are out of the zones, so to resolve this error, I had to perform a manual task. As such, I make use of Tableau function - "Annotate" which allows me to select a specific mark and retrieve the x,y coordinates. This process is repeated until all the centre point has been fixed. Finally, I have successfully created the x,y coordinates for the fixed-prox dataset.

5 ky.png

For both the fixed-prox and mobile-prox datasets, I split up the prox-id column and created 2 new columns: EmployeeId and NumPassGiven by using Excel Formula.

  • EmployeeId matches the the employeelist which is by joining the 1st character of the Firstname + lastname and transform them in lowercase. Additionally, it is derived by using Excel - LEFT (C2, (FIND ("0”, C2)-1))

Extract all characters starting on the left side until it reaches the character “0” and -1 to remove the “0”.

  • NumPassGiven is the number of times an employee picks up his/her new prox card. Furtherore, it is derived by using Excel - RIGHT(C2,3). Extract the last 3 characters starting from the right.


Interactive Visualization

The interactive visualization can be accessed here:https://public.tableau.com/profile/lim.kim.yong#!/vizhome/VA_Assignment3_Final6/Home_Page

The resolution of the visualization is custom set at the size of 1280 x 700 for a better user experience.Throughout all the different dashboards, useful tips/sharings will be provided to assists users in navigating through the different filters and actions so that their analysis can be performed smoothly.

Home Dashboard

A homepage is created with 6 different data categories in mind - Home, Employee Activity, HVAC System, Power Consumption, Exhaust Fan and Chemical. Each of these categories are further broken down into its respective sub-categories for the ease of users to perform their analysis. As such, users can select any categories that they are interested in to conduct their investigations.

The following shows the home dashboard:

Home ky.png

Employee Activity

The following shows the employee movement dashboard:

Employee ky.png

Based on the given dataset, GAStech has 7 departments: Administration, Engineering, Executive, Facilities, HR, Information Technology, and lastly Security. I have decided to use tableau to visualize how does a typical day look like for GAStech employees by the various departments.

To assist with my exploration, I decided to use “Sort”, “Filter” and “Pages” to show the movements of employees from all the different departments throughout a typical day. Below are some of the screenshots that I got after using “Filter”, “Sort” and “Pages” functions.

The “Pages” shelf creates a set of pages, with a different view on each page. For e.g. the view below shows the movements of all employees from various departments and floor for each hour throughout the entire 2 weeks (31st of May to 13th of June).

Q1)Typical Patterns In Proximity Card Data & Typical Day Of GAStech Employees

The following shows the typical routine for GAStech employees in a specific department in general:

Department Activities
Administration
  1. Administration employees start entering into the building between 7am to 9am. They will report to their office either at floor 2 or floor 3.
  2. Between 11am to 1pm, Administration employees will take the elevators/stairs to floor 1 and go for their lunch break till around 2pm.
  3. At 3pm, all Administration employees were not being detected by any sensors. I have speculated that they might had gone out for a tea break session.
  4. Lastly, between 5-6pm, Administration employees would have started leaving the building.
Executive
  1. Executive employees start entering into the building between 7am to 9am.
  2. At 9am, movements of the executive employees are mostly detected at floor 3. This might be due to their offices located at floor 3.
  3. Between 11am to 1pm, executive employees will take the elevators/stairs to floor 1 and start leaving for their lunch break. At around 12pm, movements of CEO Sten Sanjorge Jr. around the building was noticed and at around 2pm everyone will be back from lunch.
  4. At 3pm and 4pm, none of the executive employees are being detected by any sensors in all floors. I speculate that they might have gone out for outside meeting or tea break session.
  5. Lastly, by 6pm, all the executive employees would have already left the building and they are often the last department to be seen at floor 3 other than the Facilities department.
Engineering
  1. Engineering employees start entering into the building between 7am to 9am.
  2. At 9am, movements of the Engineering employees are mostly detected at floor 2. This might be due to their offices located at floor 2.
  3. Between 11am to 1pm, Engineering employees will take the elevators/stairs to floor 1 and go for their lunch break till around 2pm.
  4. Most Engineering employees will leave at around 5 or 6pm. However, Employee Clemencia, Penney, and Twana were often seen as the last few employees to leave the building at around 11pm.
Facilities
  1. Facilities employees in this department are the only ones performing a 24hour shift work duties except for the weekends.
  2. For instance, Employee Varro and Employee Emile were often detected at Floor 1 during the night time starting at 12am. Also, at 2am, they will always be detected at Floor 1_Zone 6_Conf office_1030. And at 5am, only Varro will be detected at Floor 1_Zone 6_Conf office_1030.
  3. At around 9am, some employees from the facilities department will proceed to deli.
  4. Between 11am to 1pm, Facilities Employees will take the elevators/stairs to floor 1 and go for their lunch break till around 2pm.
Human Resource (HR)
  1. HR Employees start entering into the building between 7am to 9am.
  2. At 9am, movements of the HR employees are mostly detected at floor 3. This might be due to their offices located at floor 3.
  3. Between 11am to 1pm, HR employees will take the elevators/stairs to floor 1 and go for their lunch break till around 2pm.
  4. At 3pm-4pm, HR employees are not detected by any sensors in all floors. I speculate that they might have gone out for a tea break session.
  5. Lastly, at around 5pm, HR employees will start leaving the building.
Information Technology
  1. IT Employees start entering into the building between 7am to 9am.
  2. At 9am, movements of the IT employees are mostly detected at floor 2. This might be due to their offices located at floor 2.
  3. Between 11am to 1pm, IT employees will take the elevators/stairs to floor 1 and go for their lunch break till around 2pm.
  4. At 9am and 2pm, Some of the IT employees like Sven, Celestina are often detected at Floor 3 to provide IT support.
  5. At 4pm, IT employees were often seen gathering at floor 2_zone 4_Mech/Elev. Maybe they are going for their tea break.
  6. There are some IT employees who often stay till 11pm daily.
Security
  1. Security employees start entering into the building between 7am to 9am.
  2. Employee Stenig and Varja are mostly detected in Floor 1, Zone 7 Office 1010 and Zone 8 Office 1020 respectively. Additionally, only Employee Felix is detected on Floor 3 as his office is located in that floor.
  3. Between 11am to 1pm, IT employees will take the elevators/stairs to floor 1 and go for their lunch break till around 2pm.
  4. Lastly, at around 5pm, Security employees will start leaving their offices/the building.

Based on the information gathered above, the typical day for GAStech employees, in all departments:

  1. Employees start entering into the building at 7am. By 9am, majority of the employees would have already reached their compartment/office.
  2. Lunch break is usually in between 12pm to 2pm.
  3. By 2pm, most of the employees will be back as observed by the large amount of movements/activities occurring during that period in all level of floors.
  4. Employees typically ends work at around 5-6pm.
  5. After 6pm, most of the departments would have left except employees from the Facilities,Engineering and IT department.
  6. After 7pm, employees working in level 3, mainly executives, would have left the office.
  7. At 12am, most of the employees would have left the building except for Facilities department who are on 24-hour rotational shift.
  8. It is always the same people in facilities department that perform the night shift(Employee Stenig and Varja are found in Floor 1 as their offices are located in that floor).
  9. Most GAStech employees do not work during the weekends. However, a few of the employees from the administration department came back during the weekends and work from 8am onwards till latest 3pm.
  10. Some Employees from the Engineering & IT departments often stay till 11pm-12am.


HVAC Control System Dashboard - Heating

When creating the dashboard, Heating, Ventilation and Air-Conditioning comes to my mind to segregate them into three different dashboards rather than putting everything onto one dashboard. The following shows the HVAC(Heating) dashboard:

VAV Heat KY.png

The visualizations created are based on these attributes and their units:

  • Water Heater Tank Temperature (C): Temperate of the water inside the hot water heater(Tank)
  • Water Heater Setpoint: Temperature you have set to maintain.
  • Supply Side Inlet Temperature (C): Temperature of water entering the hot water heater.
  • Supply Side Outlet Temperature (C): Temperature of the water exiting the hot water heater
  • Pump Power (W): Power used by the hot water system pump.
  • Water Heater Gas Rate (W): Rate at which the water heater burns natural gas
  • Supply Side Inlet Mass Flow Rate (kg/s): Flow rate of water entering the hot water heater.
  • Loop Temp Schedule: Temperature set point of the hot water loop. This is the temperature at which hot water is delivered to hot water appliances and fixtures

HVAC Control System Dashboard - Ventilation

The following shows the HVAC(Ventilation) dashboard:

VAV Vent KY.png

The visualizations created are based on these attributes and their units:

  • Supply Fan: Fan power (W) - Power used by the HVAC System Fan
  • Supply Fan Outlet Temperature (C) - Temperature of the air exiting the HVAC System fan
  • Supply Fan Outlet Mass Flow Rate (kg/s) - Total flow rate of air delivered by the HVAC system fan to the zones it serves
  • Air Loop Inlet Temperature(C) - Mixed Temperature of air returning to the HVAC system from all zones it serves
  • Air Loop Inlet Temperature(C) - Mixed Temperature of air returning to the HVAC system from all zones it serves
  • Air Loop Inlet MFR (kg/s) - Total flow of air returning to the HVAC system from all zones it serves
  • Drybulb temperature (C) - Drybulb temperature of the outside air
  • Outdoor Air Mass Flow Rate (kg/s) - Flow rate of outside air entering the HVAC System
  • Outdoor Air Flow Fraction - % of total air delivered by the HVAC system that is from the outside
  • Cooling Coil Power(W) - Power used by the HVAC System cooling coil
  • Heating Coil Power(W) - Power used by the HVAC System heating coil


HVAC Control System Dashboard - Air Conditioning

The following shows the HVAC(Air Conditioning) dashboard:

VAV AC KY.png

The visualizations created are based on these attributes and their units:

  • Night Cycle Control Status: ON/OFF status of the HVAC system during periods when system is normally scheduled off.
  • Thermostat Cooling Setpoint (C): Cooling set point schedule for the zone
  • Thermonstat Heating Setpoint(C): Heating set point schedule for the zone
  • Thermostat Temp (C): Temperature of the air inside the zone
  • Supply Inlet Temp(C): Temperature of the air entering the zone from its air supply box
  • Supply Inlet Mass Flow Rate(kg/s): Flow rate of the air entering the zone from its air supply box.
  • Reheat Damper Position: Position of the zone's air supply box damper. 1 corresponds to fully open, 0 corresponds to fully closed.
  • Reheat Coil Power (W): Power used by the Zone air supply box reheat coil.

Power Consumption Dashboard

The following shows the Power Consumption dashboard:

Power KY.png

Exhaust Fan Dashboard

The following shows the Exhaust Fan dashboard:

Exhaust KY.png

Chemical Dashboard

The following shows the Exhaust Fan dashboard:

Chemical KY.png

Now that we have created all the necessary dashboard, we are ready to use it as a platform to conduct our exploration and analysis.

Patterns & Anomalies

Interesting patterns that appear in the building data and describe what is notable about the pattern

S/N Interesting Pattern Significance
1
On floor 1 and 2, the bathroom exhaust fan is turn on continuously throughout the whole day. However, on floor 3, the bathroom exhaust fan power is only consuming power between 7am to 10pm. Through this pattern, we can see that floor 1 & floor 2 does not comply with the energy efficiency standards. Knowing that energy are non-renewable resources and will eventually run out. Adopting best practices to conserve energy not only helps to conserve resources but also translates into cost savings.
2
In general, most energy usages were consumed within the corridor areas throughout all floors. This is exceptionally bad for the company as the corridor spaces do not contribute greatly to employee's productive or efficiency. Furthermore, not only does it contributes to energy wastages, it causes the company to incur unnecessary costs. Therefore, management should come out with policies to curb such issue.
3
The server room at Floor 3, Zone 9 has been constantly using a huge amount of energy. It is not surprising that server room usually consumed the largest amount of equipment power.Management should know such situation and make necessary energy efficiency measures so that resources would be deployed properly.


Reference

Below are some works I personally admire and learning from it.