Difference between revisions of "IS428 AY2019-20T1 Assign Kok Jim Meng Tasks Questions and Answers"

From Visual Analytics for Business Intelligence
Jump to navigation Jump to search
Line 91: Line 91:
 
[[File:Jim Task1 Image2.png|600px|center]]
 
[[File:Jim Task1 Image2.png|600px|center]]
 
</td>
 
</td>
 +
</tr>
 
<tr>
 
<tr>
 
<td style="border: 1px solid #a7a2a2;">
 
<td style="border: 1px solid #a7a2a2;">
Line 98: Line 99:
 
[[File:Jim Task1 Image3.png|600px|center]]
 
[[File:Jim Task1 Image3.png|600px|center]]
 
</td>
 
</td>
 +
</tr>
 +
<tr>
 +
<td style="border: 1px solid #a7a2a2;">
 +
When indicating all the radiation classification for the static sensors, as compared to the rest of the static sensors, only S-15 has no value from 8 April 2020 10.06pm and the value has resumed from 10 April 2020 8.45pm onwards. Probably during that period, S-15 is faulty as it is the only static sensor that is placed very near to the nuclear power plant and most likely both earthquake and the plant leakage were occurred during that period.
 +
</td>
 +
<td style="border: 1px solid #a7a2a2;">
 +
[[File:Jim Task1 Image5.png|600px|center]]
 +
</td>
 +
</tr>
 
</table>
 
</table>

Revision as of 21:00, 12 October 2019

StHimarkNeighborhoodMap.png IS428 VAST 2019 Mini Challenge 2

Problem & Motivation

Data Preparation

Interactive Visualisation

Tasks Questions and Answers

References and Comments

 

Tasks Questions and Answers

Task 1

Dashboard

Jim Task1 Dashboard.png

The dashboard provides a total of 3 visuals:

1. Map of the Mobile Sensors and Static Sensors throughout the period from 6 April 2020 to 10 April 2020
Map that provides the location of the sensors of their whereabouts since 6 April 2020 to 10 April 2020. Serves as a filter to filter the other charts. Hover to see the sensor id, its radiation value, the location coordinates, and the timestamp in minutes.

2. Radiation Measurement (Maximum) for Mobile Sensors in Minute of the Timestamp
A time-series chart based on minutes by using a sample size of maximum radiation measurement value from 0 to 5000 of the mobile sensors. Marked by colour intensity where light blue is low and dark blue is high. Hover to see the sensor id and its radiation value.

3. Radiation Measurement (Maximum) for Static Sensors in Minute of the Timestamp
A time-series chart based on minutes by using a sample size of maximum radiation measurement value from 0 to 5000 of the static sensors. Hover to see the sensor id and its radiation value.

Task 1 Questions & Answers

Visualize radiation measurements over time from both static and mobile sensors to identify areas where radiation over background is detected. Characterize changes over time. Limit your response to 6 images and 500 words.

Description
Images

When the radiation measurement of a sensor has reached a minimum value of 100 CPM, it is at the dangerous radiation level. According to the International Nuclear and Radiological Event Scale, there are 8 classes of radiation classification as follows:

  • Deviation
  • Anomaly
  • Incident
  • Serious Incident
  • Accident with local consequences
  • Accident with wider consequences
  • Serious accident
  • Major accident

Hence, we will choose “6. Accident with wider consequences”, “7. Serious accident”, and “8. Major accident” to find out where do these radiation classifications are detected as these classifications are range from 100 CPM onwards.

In the map, the blue dots indicate the mobile sensors while the orange dots indicate the static sensors.

Based on the timeline of April 6 2020 12.37am to April 10 2020 11.59pm, most of the high radiation occur in the north and central part of St Himark such as:

  • Old Town
  • Weston
  • Easton
  • Downtown
  • Southton
  • West Parton
  • East Parton

This is most likely that the radioactive contamination has spread from the nuclear plant from Safe Town to its nearby regions.

Jim Task1 Image1.png

While selecting M-9 during that timestamp as a filter in the dashboard, sensor M-9 is actually near the nuclear plant in Safe Town.

We assume that since that timestamp strikes, the radiation contamination has started to take place as according to the time-series chart.

Jim Task1 Image2.png

With the same indication of the radiation classification as mobile sensors’, for the static sensors, only S-15 has the high radiation measurement as the sensor is fixedly placed near the nuclear plant in Safe Town after selecting S-15 in the time-series chart of static sensors as the filter in the dashboard.

Jim Task1 Image3.png

When indicating all the radiation classification for the static sensors, as compared to the rest of the static sensors, only S-15 has no value from 8 April 2020 10.06pm and the value has resumed from 10 April 2020 8.45pm onwards. Probably during that period, S-15 is faulty as it is the only static sensor that is placed very near to the nuclear power plant and most likely both earthquake and the plant leakage were occurred during that period.

Jim Task1 Image5.png