Q3

From Visual Analytics and Applications
Jump to navigation Jump to search

Blue.gif ISSS608 Visual Analytics and Applications


About

Q1

Q2

Q3

 


WIND SPEED TRENDS:

float

Wind speed analysis is done to understand the speed of the wind for each month and identify the day that experienced a lot of chemical release due to the wind speed. The charts shown describe the wind speed for each chemical released on a particular day. The color refers to the average reading of chemical and the thickness of the lines represent the wind speed intensity.
There is no wind data available from 1st August to 3rd August. So the findings are based on rest of the days in July, August and December.

Wind speed trends for each chemical:

1. AGOG- 3A:
In July, when the wind speed was low, the sensors were able to capture AGOG-3A release; Hence the high amount of AGOG-3A release on the two days is due to the wind speed being low and on the other days since the wind speed was high, the chemical readings captured is low.
In August, 13th experienced a high reading of this chemical , and all the peak wind speed days experienced above average AGOG -3A release.
In December, above average release of AGOG-3A is uniformly observed throughout the month. Hence we can that the reason for not seeing high AGOG-3A value is because of the wind speed.

2. METHYLOSMOLENE:
July and August have relatively low reading and the wind speed has no impact on the release of Methylosmolene.

float

In December, it is observed that on the days of low wind speed, the release of Methylosmolene is high when compared to the days with high wind speed.

3. APPLUIMONIA:
Compared to three months, December shows high release of Appluimonia throughout the month independent of the speed of the wind.

4. CHLORODININE:
Cholorodinine also exhibits similar pattern as Appluimonia in its behaviour, however traces of excess release of this chemical is seen in April.

According to the analysis made earlier on the chemical release readings of Appluimonia and Cholorodinine, it was observed that the readings are low compared to AGOG- 3A and Methylosmolene. But the graphs here show a different picture. The release of is much higher than seen earlier. This could be the result of wind speed. December month has strong winds and this could be the reason for reading such high chemical releases.

In conclusion,as predicted earlier while analyzing chemical release patterns we can say that the readings of chemicals captured by the sensors are affected by the wind speed. Further analysis needs to be performed on the wind direction and the factories that release these chemicals to gain better insights.